nanoLC-Ultra systemThe next generation NanoLC system from Eksigent promises to deliver high resolution separations, combined with excellent reproducibility, resulting in improved identification of low abundance peptides/proteins with nanoLC-MS.
The higher pressure capability of the NanoLC-Ultra platform allows the use of longer columns and/or columns packed with smaller particles for higher resolution separations of complex (digested) protein samples. Moreover, the NanoLC-Ultra family features self-priming and self-purging pumps for easier changing of solvents, and a temperature-controlled column compartment for maintaining exceptional retention time reproducibility.
Eksigent’s proven Microfluidic Flow Control™ (MFC) technology guarantees reliable and reproducible results, while integration with major mass spectrometer software packages makes the system a seamless addition to almost any nanoLC-MS workflow.
A range of different NanoLC-Ultra system configurations are available for various proteomics applications—from single gradient systems for direct sample injection, to dual gradient systems for multidimensional separations, and dual column set-up for increased throughput.
Key advantages of the new NanoLC-Ultra series
A NanoLC-Ultra system is the proteomics lab workhorse, delivering stable, reproducible gradient separations for peptide/protein identification, phosphopeptide analysis, biomarker discovery, metabolomics and more.

Figure 1. Retention time reproducibility of the NanoLC-Ultra System
This figure shows eight consecutive separations of a peptide test mix on a 75 µm ID x 15 cm C18 NanoLC column. Back pressure was 9,000 psi. The RSD’s on retention time are less than .3% for all components.
The operating pressure of 10,000 psi obtained with the NanoLC-Ultra system enables the use of longer columns, or columns packed with smaller particles, for the analysis of increasingly complex proteomics samples (see Figure 2).

Figure 2. High resolution separation of a BSA tryptic digest.
Separation of a BSA tryptic digest on a 75 µm ID x 40 cm column packed with 3 µm C18 stationary phase. Back pressure was 6,000 psi. The peak capacity for this separation is approximately 150.
Elevated temperatures also can be utilized to decrease column pressure and/or improve separation efficiency. For advanced applications like sample pre-concentration or dual-column set-up, the NanoLC-Ultra system offers up to two 10-port nano valves rated at 10,000 psi that are integrated into the column compartment. These 10-port valves have an extremely low port-to-port volume of <25 nL, along with a proprietary coating that increases the lifetime of the valve and reduces sample loss.
Click here to download the data sheet
Flexible system configurations for proteomics applicationsCurrently, four configurations of the NanoLC-Ultra series are available for proteomics researchers: the NanoLC-Ultra 1D, NanoLC-Ultra 1Dplus, NanoLC-Ultra 2D, and NanoLC-Ultra 2Dplus.
NanoLC-Ultra
The NanoLC-Ultra 1D system contains one binary gradient pump, allowing for direct on-column injections. The NanoLC-Ultra 1Dplus system adds an isocratic loading pump for sample enrichment experiments in which sample is loaded onto a trap column prior to analysis on a NanoLC column.
NanoLC-Ultra 2D systems include all of the features of the 1D, plus the added capability of automated 2-dimensional chromatography. The NanoLC-Ultra 2D (two gradients) system and NanoLC-Ultra 2Dplus system (two gradients and one isocratic loading pump) are designed for advanced applications such as on-line 2D LC or high throughput set-ups using two nanoLC columns.
All NanoLC-Ultra 2D and 2Dplus systems are available with one or two built-in 10-port valves. NanoLC-Ultra 2D and 2Dplus system can be configured to run in either 2-dimensional separation mode or as two parallel, completely independent binary gradient HPLC systems.
An AS-2 autosampler and PC-based instrument control software are available with all configurations of the NanoLC-Ultra series.
AS-2 autosampler
The new NanoLC-Ultra sits atop the new AS-2 autosampler and can be operated by our integrated Eksigent Control Software.
The flexible and easy-to-use autosampler employs a 2.4 ul volume needle for injection of small volumes without sample losses. The needle is coated with a proprietary inert coating on both the inside and outside to prevent sample losses due to adsorption. The sample compartment is completely enclosed to ensure temperature control down to 4°C. Capacity is two microtiter plates or 96 vials. Using two different wash positions, the needle is washed inside and outside to reduce carry-over. The 6-port injection valve has port-to-port volumes of <25 nl, and is rated to 10,000 psi. A proprietary coating on the valve stator and rotor assures excellent valve reliability and reduces sample adsorption.
Dimensions Weight Working temperature Power Maximum pressure Standard flow rate ranges
Flow rate accuracy Flow rate precision Gradient accuracy Gradient delay Column oven Built-in 10-port valve
Wetted parts I/O
Instrument control Dimensions Weight Working temperature Power Capacity Injection valve
Injection volume Dispenser syringe 25 µl standard; optional : 100 µl, 250 µl Injection volume reproducibility
Carry-over Sample tray cooling Wetted parts I/O
Instrument control
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||